CONTACT US:400-609-2378
current location :Home >> Product >> Heat Resistant Coating >> W61-011 High temperature resistant insulating paint
W61-011 High temperature resistant insulating paint

W61-011 High temperature resistant insulating paint

Composition: This paint is made by organic silicon resin, acrylic acid and ethanol.
Performance: This paint has the advantages of light color, strong adhesion, excellent heat resistance, oil resistance and insulation, and has the characteristics of low temperature drying and rapid drying.
Application: The paint can be used in circuit board, electronic products and other metal surface requiring insulation, heat resistance and corrosion protection.

Product specification

Temperature resistant range Paint film color Coating types Mixing  proportion
200℃ Black, white, grey, red, yellow, blue, green, aluminum pink, and other colors Finish paint, primer, One-component
300℃ Black, white, grey, red, yellow, blue, green, aluminum pink, and other colors Finish paint, primer, One-component

Technical parameters

Item Index
Viscosity(painting -4) 20~40s
Drying time Baking:200℃ 10-20min
Flexibility ≤2mm
Adhesion ≤2级
Impact strength ≥50kg·cm
Heat resistance(200-300℃ 2h) No foaming, no crack

Construction method

1、Base material processing
The coated base material surface must carry out thorough removal of grease, scale, rust, old coating, and etc., using shot or sand blasting method, to reach Sweden derusting standard Sa2.5 grade and roughness of 30-70μm, manual derusting methods can also be adopted to reach Sweden derusting standard St3 grade and roughness of 30-70μm.
2、Baking (applicable for one-component paint)

Product name Baking temperature Holding time
High temperature resistant insulating paint 180℃ 20min
200℃ 10min

3、Construction conditions
Coating operation shall be performed as soon as possible after the substrate processing, generally not exceeding 8 hours. The substrate surface temperature and environmental temperature are generally no less than 10℃, the surface temperature shall be at least 3℃ higher than the dew point temperature, and the relative humidity of the air shall not exceed 85%.
4、Coating method
This coating can use brush coating, airless spraying and auxiliary air spraying method for construction.
5、Dilution
Generally the coating shall use the matching thinner to adjust viscosity and cleaning tools.
6、Coating intervals
One-component paint can carry out later coating after drying. If it is dry at room temperature, the coating time intervals as follows:

Substrate temperature 5℃ 20℃ 30℃
Shortest 48h 24h 16h
Longest No limit